Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with DA. DA in the sample or standard competes with a fixed amount of biotin-labeled DA for sites on a pre-coated antibody specific to DA. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of DA in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti IL-17 antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of IL-17 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with FSH. FSH in the sample or standard competes with a fixed amount of biotin-labeled FSH for sites on a pre-coated antibody specific to FSH. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of FSH in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with CORT. CORT in the sample or standard competes with a fixed amount of biotin-labeled CORT for sites on a pre-coated antibody specific to CORT. Read the O.D. absorbance at 450nm in a microplate reader. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of CORT in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti Casp3 antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of Casp3 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with MDA. MDA in the sample or standard competes with a fixed amount of biotin-labeled MDA for sites on a pre-coated antibody specific to MDA. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of MDA in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti MPO antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of MPO in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with 8-OHdG. 8-OHdG in the sample or standard competes with a fixed amount of biotin-labeled 8-OHdG for sites on a pre-coated antibody specific to 8-OHdG. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of 8-OHdG in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with CORT. CORT in the sample or standard competes with a fixed amount of biotin-labeled CORT for sites on a pre-coated antibody specific to CORT. ead the O.D. absorbance at 450nm in a microplate reader. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of CORT in the sample. The concentration of the target substance is inversely proportional to the OD450 value.